The Question/Answer period for this 470 has expired.


Questions already answered for this 470 will show below.


Q: Can you verify when the customer will make a final decision on this project? Also, I see that an extension was granted. Can you verify when this proposal will be closed to bidding?
A: Update / clarification: Decisions for Great Circle have almost been completed and we will file prior to the close of the 471 window. The due date for this opportunity has past. Sorry for the confusion. I thought you were asking about De La Salle.

Q: Can you help me with the following: - What firmware version are you running on your controller? - What are the models of your current Access Points?
A: At present, the version of firmware is 09.21.06.0006. The access points are 3508 and 3610 and 3715.

Q: Additional questions: Controller: - What controller model do you have? Can you please confirm if it is a C25? - How many current available licenses do you have? - How many existing AP's do you have? Are you replacing all of them? If you are not replacing all of them, what is the model? Cabling: - Can you verify that you do not need any new network drops for those AP's? I didn't see them on your RFP
A: Controller: - What controller model do you have? Can you please confirm if it is a C25? No. C4110 - How many current available licenses do you have? 100 - How many existing AP's do you have? 86 in use Are you replacing all of them? No If you are not replacing all of them, what is the model? See ITB for requested model Cabling: - Can you verify that you do not need any new network drops for those AP's? Verified Please provide your quote based on the information provided in the ITB.

Q: Access Points: 1 - You have basic maintenance of internal connections listed. Does this mean you just need support or are you wanting 22 new AP's? 2 - Do you have enough licenses to handle the expansion of those 22 access points if we are adding new hardware? 3 - What controller do you currently have? I want to make sure that the new AP's will integrate into your environment. Racks: - What size are you looking for? 6U, 8U, etc. UPS: What run time are you looking for? 30 min, 60 min, etc.
A: 22 new APs with licensing (note the AP models). 8U and 30 minutes should suffice.

Q: Do you really want a second circuit in Springfield?
A: Actually, please terminate (price) the service to 18610 East 37th Terrace, Independence, MO 64057